This release adds charging schedules: a charger can now be set to deliver power only during the hours you choose, which suits loads such as engine heaters. Spot optimization can keep a car charging at a low current instead of pausing it completely, a choice drivers can also make in the Driver app, and the other cars on the site now get a paused car's share of the capacity. In Pulse, the automations list gets filters, bulk actions and the jobs you schedule from a charger's page, and status automations can be limited by the text of the charger's message. Stuck sessions can now be closed from Connect with a force stop, and the platform can also find and close them automatically.
Charging schedules
You can now decide at which hours a charger delivers power. Under Charger > Energy management, the new Charging schedule card holds the time windows in which the charger is allowed to charge. Outside them the charger is held at 0 A, and inside them it gets its normal share of the site's capacity. A typical use is an engine heater that is plugged in the evening before but should only run in the hours before the morning drive.
-
A schedule can have up to 14 time windows. Each has a start time and an end time, and either repeats on the weekdays you select or happens once on a date you pick.
-
A window whose end time is before its start time runs past midnight and ends the next day.
-
A window can be switched off without removing it.
-
Times are in the local time of the charger's site.
-
A session that is plugged in outside a window stays open and starts charging when the next window opens.
-
A charger with a schedule is not spot optimized. The schedule alone decides when it charges.
-
Schedules can also be read and replaced through the API, with
GETandPUT v2/dlm/chargers/{chargerId}/charger-schedule.
Charging schedules work for OCPP chargers on sites that have DLM enabled. Easee and Zaptec DLM sites are not supported yet.
Spot optimization
Minimum current while paused
Some cars go to sleep when charging is paused completely and do not wake up when it resumes. To avoid that, you can now give a charger a minimum current for the expensive periods. Under Charger > Energy management, the Spot optimization card has a new field, Minimum current while paused (A). With a value set, the charger keeps charging at that current while spot optimization would otherwise pause it.
-
The value is 0 or between 6 and 32 A. Empty or 0 means the charger pauses completely, as before.
-
The minimum gives way to other cars. When the site's capacity is needed by cars that are not paused, the paused car goes to 0 A.
-
The setting applies on OCPP DLM sites. It is not shown for Easee and Zaptec sites, and it has no effect on sites that have a transaction minimum current set.
The setting shows when a price-based charging profile is chosen. It applies on sites that allow driver-level spot optimization, and there the driver's choice takes priority over the charger's setting.
-
Use the charger's setting: what you have set for the charger applies. This is the default. -
Stop charging completely: charging pauses fully, even when the charger has a minimum current. -
Keep charging at 6, 8, 10, 13 or 16 A: charging continues at that current when the site has capacity to spare.
Drivers can make the same choice for their own sessions in the Driver app. On the Info page, the smart charging card has a new setting, While charging is paused:
Pause choice in the Driver app
Paused cars no longer hold back the others
When spot optimization pauses a car, the other cars on the site now get its share of the site's capacity. Before, they stayed at a reduced current for the whole expensive period.
Pulse automations list
The list under Pulse > Automations is easier to work with when you have many automations.
-
Filters. Filter the list by type (Automation or Scheduled job), status, trigger and home site, with or without subsites.
-
Scheduled jobs. The reboots and unavailability periods you schedule from a charger's page now show in the list as scheduled jobs, newest first, with the charger, the sockets and the time range. You can filter them by charger.
-
Bulk actions. Select several automations and activate, deactivate or delete them in one go. Scheduled jobs can be deleted the same way.
Message conditions on status automations
Automations with the Charger sends status update trigger can now be limited by the text of the message the charger sends. The single message pattern is replaced by two lists:
-
Message contains: the automation fires when the message contains any of these texts. Leave it empty to fire on any message. -
Except when message contains: a message that contains any of these texts never fires the automation. This always wins over the first list.
This makes rules such as "reboot on any error except PowerMeterFailure" possible. The texts are matched as typed, and upper and lower case do not matter.
An earlier "contains" condition opens as a text in the first list. Other earlier conditions are shown as Earlier message condition and keep applying until you remove them.
Automations require an active Pulse subscription. If you want to hear more, please don't hesitate to contact us!
Force stop for stuck sessions
If a charger never reports that a session has ended, the session stays open on our side.
You can now close these sessions from Connect. Open the socket's page, choose Force stop, enter a reason and confirm.
-
If the charger is online, it first gets a normal remote stop. We then wait 60 seconds. If the charger stops the session in that time, the session ends as usual.
-
If the session is still open after 60 seconds, or the charger is offline, we close the session ourselves.
-
The session is saved with the last meter value the charger sent, and ends at the time that value was measured. If the charger sent no meter values, the session is saved with 0 kWh.
-
The platform also detects stuck sessions automatically and closes them the same way.
Other features released
-
Session charts now place each meter value at the time the charger reported it. Before, values that arrived late were drawn at the time they were received.
-
The automation rules API has three new optional filters on
GET v2/automation/rules:triggerType,homeSiteIdandincludeSubsites. -
When a charger does not report a meter reading at the start of a session, the session now shows 0 kWh and 0 cost, both while charging and after it ends. Before, such a session could show the charger's whole lifetime meter reading as its consumption.
-
Roaming partners now get live updates during roaming sessions on chargers that start charging without a separate authorisation step, such as self-onboarded Easee and Zaptec chargers. Before, the partner only got the start and the end of these sessions.
-
Plug & Charge sessions started with a contract issued through eMabler are now linked to the driver who owns the contract.
-
A charger that sends an empty RFID tag is no longer matched to any tag, and the authorisation is rejected.
-
Session data sent to integrations now includes the utility metering point ID of the site, when charger details are enabled for your integration.
-
Other small bug fixes.